Péptido antimicrobiano AP7121: inhibición de adhesión bacteriana en catéteres vasculares

Péptido antimicrobiano AP7121 en catéteres

Autores/as

  • S Lissarrague Facultad Ciencias Médicas, Universidad Nacional del Centro de la Provincia de Buenos Aires, Argentina https://orcid.org/0009-0004-0524-2620
  • L Schofs Laboratorio de Farmacología, Facultad de Ciencias Veterinarias, Universidad Nacional del Centro de la Provincia de Buenos Aires, Argentina- CIVETAN- CONICET https://orcid.org/0000-0002-3955-601X
  • M Bistoletti Facultad Ciencias Médicas, Universidad Nacional del Centro de la Provincia de Buenos Aires, Argentina https://orcid.org/0009-0001-2233-1201
  • L García Allende Hospital Privado de Comunidad de Mar del Plata, Argentina https://orcid.org/0009-0007-0980-0716
  • A Lallée Facultad Ciencias Médicas, Universidad Nacional del Centro de la Provincia de Buenos Aires, Argentina https://orcid.org/0009-0008-9773-4604
  • B Baldaccini Facultad Ciencias Médicas, Universidad Nacional del Centro de la Provincia de Buenos Aires, Argentina
  • S Sánchez Bruni Laboratorio de Farmacología, Facultad de Ciencias Veterinarias, Universidad Nacional del Centro de la Provincia de Buenos Aires, Argentina- CIVETAN- CONICET https://orcid.org/0000-0002-9598-6786
  • M Sparo Facultad Ciencias Médicas, Universidad Nacional del Centro de la Provincia de Buenos Aires, Argentina https://orcid.org/0000-0002-0768-894X

DOI:

https://doi.org/10.18633/biotecnia.v25i2.1858

Palabras clave:

péptido antimicrobiano AP7121, catéter vascular, adhesión bacteriana, inhibición

Resumen

Las infecciones del torrente sanguíneo asociadas a los cuidados de la salud constituyen una de las principales causas de morbilidad y mortalidad. La infección relacionada con catéteres vasculares es su fuente principal. Las bacterias Gram positivas, especialmente Staphylococcus spp., constituyen uno de los agentes etiológicos más frecuentes. Objetivo: evaluar la actividad inhibitoria del AP7121 sobre la adherencia de Staphylococcus aureus en catéteres vasculares. Se utilizó la cepa productora de biofilm S. aureus ATCC 35556 (SA). Se estimó CIMAP7121 para SA, se inocularon segmentos de 20 mm de catéter vascular (n=3) con 104 UFC mL-1 de SA. Se probaron tres esquemas diferentes (A: simultáneo, B: anterior y C: después del desafío bacteriano) utilizando 1 x CIMAP7121. Se incluyeron grupos de control en cada esquema. La CIMAP7121 fue 0,48 mg/L. Con los esquemas A y B se logró una reducción de 2 logaritmos que representa una disminución del 99 % de células viables. El tratamiento posterior a la exposición con AP7121 (esquema C) produjo una reducción de 1 logaritmo que representa una disminución del 90 % de células viables. Estos resultados sugieren una rápida actividad antimicrobiana de AP7121 que podría ser beneficiosa para reducir la adherencia bacteriana en catéteres vasculares.

Descargas

Los datos de descargas todavía no están disponibles.

Citas

Bower, C.K., Bothwell, M.K. y McGuire, J. 2001. Lantibiotics as surface active agents for biomedical applications. Colloids Surfaces B: Biointerfaces. 22:259–265. DOI: https://doi.org/10.1016/S0927-7765(01)00199-0

Bower, C.K., Daeschel, M.A. y McGuire, J. 1998. Protein antimicrobial barriers to bacterial adhesion. Journal of Dairy Science. 81:2771–2778. DOI: https://doi.org/10.3168/jds.S0022-0302(98)75835-7

Cavera, V.L., Arthur, T.D., Kashtanov, D. y Chikindas, M.L. 2015. Bacteriocins and their position in the next wave of conventional antibiotics. International Journal of Antimicrobial Agents. 46, 494–501. DOI: https://doi.org/10.1016/j.ijantimicag.2015.07.011

Clinical and Laboratory Standards Institute (CLSI). 2019. Performance standards for antimicrobial susceptibility testing, 29th ed. CLSI Document M100. Wayne, PA: CLSI.

Dawson, R.M.C., Elliot, D.C., Elliot, W.H. y Jones, K.M. 1969. Data for Biochemical Research, Clarendon Press, p.622. Oxford.

Delpech, G., Bistoletti, M., Ceci, M., Lissarrague, S., Bruni, S.S. y Sparo, M. 2017. Bactericidal activity and synergy studies of peptide AP-CECT7121 against multi-resistant bacteria isolated from human and animal soft-tissue infections. Probiotics and Antimicrobial Proteins. 9: 355-362. DOI: https://doi.org/10.1007/s12602-017-9289-3

Delpech, G., Ceci, M., Lissarrague, S., García Allende, L., Baldaccini, B. y Sparo, M. 2020. In vitro activity of antimicrobial peptide AP7121 against human methicillin-resistant Staphylococcus aureus and Staphylococcus epidermidis biofilm producers. Biofouling. 36 (2): 257-267. DOI: https://doi.org/10.1080/08927014.2020.1756266

Delpech, G., Hebert, E.M., Sparo, M. y Saavedra, L. 2019. Draft genome sequence of Enterococcus faecalis strain CECT7121, a corn silage isolate with antibacterial activity against Gram-positive pathogens”. Microbiology Resource Announcements. 8:e00245-19. DOI: https://doi.org/10.1128/MRA.00245-19

Donelli, G. y Francolini, I. 2001. Efficacy of antiadhesive, antibiotic, and antiseptic coating in preventing catheter-related infections. Journal of Chemotherapy. 13:56–67. DOI: https://doi.org/10.1179/joc.2001.13.6.595

Dosler, S. y Mataraci, E. 2013. In vitro pharmacokinetics of antimicrobial cationic peptides alone and in combination with antibiotics against methicillin resistant Staphylococcus aureus biofilms. Peptides. 49: 53-8. DOI: https://doi.org/10.1016/j.peptides.2013.08.008

Fontana, M.B., de Bastos Mdo, C. y Brandelli, A. 2006. Bacteriocins Pep5 and epidermin inhibit Staphylococcus epidermidis adhesion to catheters. Current Microbiology. 52(5):350-3. DOI: https://doi.org/10.1007/s00284-005-0152-5

Gahlot, R., Nigam, C., Kumar, V., Yadav, G. y Anupurba, S. 2014. Catheter-related bloodstream infections. International Journal of Critical Illness and Injury Science. 4(2):162-7. DOI: https://doi.org/10.4103/2229-5151.134184

Godoy-Santos, F., Pitts, B., Stewart, P.S. y Mantovani, H.C. 2018. Nisin penetrates Staphylococcus aureus biofilms but shows differences in killing effects against sessile and planktonic cells. Biorxiv. 303636. DOI: https://doi.org/10.1101/303636

Hassan, M., Kjos, M., Nes, I. F., Diep, D. B. y Lotfipour, F. 2012. Natural antimicrobial peptides from bacteria: characteristics and potential applications to fight against antibiotic resistance. Journal of Applied Microbiology. 113(4): 723-736. DOI: https://doi.org/10.1111/j.1365-2672.2012.05338.x

Inoue, H. y Minghui, R. 2017. Resistencia a los antimicrobianos: del compromiso político a la acción nacional. Boletín de la Organización Mundial de la Salud. 95: 242.

Nan, L., Yang, K. y Ren, G. 2015. Anti-biofilm formation of a novel stainless steel against Staphylococcus aureus. Material Science and Engineering C. 51: 356-61. DOI: https://doi.org/10.1016/j.msec.2015.03.012

Pitiriga, V., Kanellopoulos, P., Bakalis, I., Kampos, E., Sagris, I., Saroglous, G. y Tsakris, A. 2020. Central venous catheter-related bloodstream infection and colonization: the impact of insertion site and distribution of multidrug-resistant pathogens. Antimicrobial Resistance and Infection Control. 9: 189-197. DOI: https://doi.org/10.1186/s13756-020-00851-1

Programa Nacional de Vigilancia de Infecciones Hospitalarias de Argentina. (2017). Estudio nacional de diagnóstico institucional y prevalencia de infecciones asociadas al cuidado de la salud de hospitales de Argentina. Disponible en: www. vihda.com.ar.

Seidi, K., Stucki, M., Ruegg, M., Goerke, C., Wolz, C. y Harris, L. 2008. Staphylococcus aureus CcpA affects biofilm formation. Infection and Immunity. 76: 2044-2050. DOI: https://doi.org/10.1128/IAI.00035-08

Sherertz, R.J., Raad, I., Belani, A., Koo, L.C., Rand, K.H., Pickett, D.L., Straub, S.A. y Fauerbach, L.L. 1990. Three-year experience with sonicated vascular catheter cultures in a clinical microbiology laboratory. Journal of Clinical Microbiology. 28: 76-82. DOI: https://doi.org/10.1128/jcm.28.1.76-82.1990

Sparo, M.D., Castro, M.S., Andino, P.J., Lavigne, M.V., Ceriani, C., Gutiérrez, G.L., Fernández, M.M., De Marzi, M.C., Malchiodi, E.L. y Manghi, M.A. 2006. Partial characterization of enterocin MR99 from a corn silage isolate of l Enterococcus faecalis. Journal of Applied Microbiology.100: 123-134. DOI: https://doi.org/10.1111/j.1365-2672.2005.02752.x

Sparo, M.D., Jones, D.G. y Sánchez Bruni, S.F. 2009. Assessment of the in vitro efficacy of the novel antimicrobial peptide CECT7121 against human Gram-positive bacteria from serious infections refractory to treatment. Chemotherapy. 55: 270-7. DOI: https://doi.org/10.1159/000223069

Sparo, M. 2006. Investigación de bacteriocinas de bacterias ácido-lácticas en el Partido de Tandil. Tesis Doctoral. Facultad de Farmacia y Bioquímica, Universidad de Buenos Aires, Argentina.

Wallace, A., Albadawi, H., Patel, N., Khademhosseini, A., Zhang, Y. S., Naidu, S.y Oklu, R. 2017. Anti-fouling strategies for central venous catheters. Cardiovascular Diagnosis and Therapy. 7(Suppl 3): S246. DOI: https://doi.org/10.21037/cdt.2017.09.18

Publicado

2023-05-11

Cómo citar

Lissarrague, S., Schofs, L. ., Bistoletti, M., García Allende, L., Lallée, A. ., Baldaccini, B. ., … Sparo, M. (2023). Péptido antimicrobiano AP7121: inhibición de adhesión bacteriana en catéteres vasculares: Péptido antimicrobiano AP7121 en catéteres. Biotecnia, 25(2), 165–168. https://doi.org/10.18633/biotecnia.v25i2.1858

Número

Sección

Artículos originales

Métrica

Artículos similares

1 2 3 4 5 6 7 8 9 10 11 > >> 

También puede Iniciar una búsqueda de similitud avanzada para este artículo.